Type: | Insulated |
---|---|
Conductor Type: | Stranded |
Application: | Overhead |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
0.6/1kv CU/XLPE/SWA/PVC 4 core power cable armored 120mm
600/1000 V-TWO CORE COPPER CONDUCTOR XLPE INSULATED SWA PVC SHEATHED CABLES (CU/XLPE/PVC/SWA/PVC)
NOMINAL AREA OF CONDUCTOR | MAXIMUM CONDUCTOR RESISTANCE AT 20°C | THICKNESS OF INSULATION | THICKNESS OF EXTRUDED BEDDING | DIA. OF ARMOUR WIRE | THICKNESS OF OUTER SHEATH | APPROX.OVERALL DIAMETER | APPROX.CABLE WEIGHT | STANDARD PACKING LENGTH | DRUM SIZE | APPROX.GROSS WEIGHT |
Sqmm | Ohm/Km | mm | mm | mm | mm | mm | Kg/Km | Metre±10% | KG | |
1.5* | 12.1 | 0.7 | 1 | 0.9 | 1.8 | 14.2 | 355 | 1000 | D-10 | 415 |
1.5 | 12.1 | 0.7 | 1 | 0.9 | 1.8 | 14.6 | 370 | 1000 | D-10 | 430 |
2.5* | 7.41 | 0.7 | 1 | 0.9 | 1.8 | 15 | 400 | 1000 | D-10 | 460 |
2.5 | 7.41 | 0.7 | 1 | 0.9 | 1.8 | 15.4 | 415 | 1000 | D-10 | 475 |
4 | 4.61 | 0.7 | 1 | 0.9 | 1.8 | 16.4 | 480 | 1000 | D-11 | 580 |
6 | 3.08 | 0.7 | 1 | 0.9 | 1.8 | 17.6 | 570 | 1000 | D-11 | 670 |
10 | 1.83 | 0.7 | 1 | 1.25 | 1.8 | 20.3 | 820 | 1000 | D-12 | 930 |
16 | 1.15 | 0.7 | 1 | 1.25 | 1.8 | 22.3 | 1030 | 1000 | D-14 | 1180 |
25 | 0.727 | 0.9 | 1 | 1.6 | 1.8 | 26.3 | 1530 | 1000 | D-16 | 1740 |
35 | 0.524 | 0.9 | 1 | 1.6 | 1.8 | 28.5 | 1840 | 1000 | D-18 | 2080 |
50 | 0.387 | 1 | 1 | 1.6 | 1.8 | 30.9 | 2070 | 500 | D-14 | 1190 |
70 | 0.268 | 1.1 | 1 | 1.6 | 2 | 34.9 | 2670 | 500 | D-16 | 1545 |
95 | 0.193 | 1.1 | 1.2 | 2 | 2.1 | 40.1 | 3660 | 500 | D-18 | 2070 |
120 | 0.153 | 1.2 | 1.2 | 2 | 2.2 | 43.7 | 4350 | 500 | D-18 | 2420 |
150 | 0.124 | 1.4 | 1.2 | 2 | 2.3 | 47.5 | 5160 | 500 | D-19 | 2900 |
185 | 0.0991 | 1.6 | 1.4 | 2.5 | 2.5 | 53.3 | 6600 | 250 | D-18 | 1895 |
240 | 0.0754 | 1.7 | 1.4 | 2.5 | 2.7 | 59.1 | 8100 | 250 | D-18 | 2270 |
300 | 0.0601 | 1.8 | 1.6 | 2.5 | 2.8 | 64.1 | 9660 | 250 | D-18 | 2660 |
400 | 0.047 | 2 | 1.6 | 2.5 | 3.1 | 71.3 | 12000 | 250 | D-21 | 3425 |
500 | 0.0366 | 2.2 | 1.6 | 3.15 | 3.3 | 79.8 | 15500 | 250 | D-23 | 4375 |
*Circular solid conductors (Class 1).
All other conductors Circular stranded or circular stranded compacted (Class 2).
Cables conform to BS 5467 and generally to IEC 60502 - 1.
600/1000V-THREE CORE COPPER CONDUCTOR XLPE INSULATED SWA PVC SHEATHED CABLES (CU/XLPE/PVC/SWA/PVC)
NOMINAL AREA OF CONDUCTOR | MAXIMUM CONDUCTOR RESISTANCE AT 20°C | THICKNESS OF INSULATION | THICKNESS OF BEDDING | DIA. OF ARMOUR WIRE | THICKNESS OF OUTER SHEATH | APPROX.OVERALL DIAMETER | APPROX.CABLE WEIGHT | STANDARD PACKING LENGTH | DRUM SIZE | APPROX.GROSS WEIGHT | ||||
Extruded Bedding | Lapped Bedding | Extruded Bedding | Lapped Bedding | Extruded Bedding | Lapped Bedding | Extruded Bedding | Lapped Bedding | |||||||
Sqmm | Ohm/Km | mm | mm | mm | mm | mm | Kg/Km | Metre±10% | KG | |||||
1.5* | 12.1 | 0.7 | 0.8 | - | 0.9 | 1.3 | 13.3 | - | 330 | - | 1000 | D-10 | 390 | - |
1.5 | 12.1 | 0.7 | 0.8 | - | 0.9 | 1.3 | 13.7 | - | 350 | - | 1000 | D-10 | 410 | - |
2.5* | 7.41 | 0.7 | 0.8 | - | 0.9 | 1.4 | 14.4 | - | 390 | - | 1000 | D-10 | 450 | - |
2.5 | 7.41 | 0.7 | 0.8 | 0.9 | 1.4 | 14.8 | - | 415 | - | 1000 | D-10 | 475 | - | |
4 | 4.61 | 0.7 | 0.8 | - | 0.9 | 1.4 | 15.9 | - | 490 | - | 1000 | D-11 | 590 | - |
6 | 3.08 | 0.7 | 0.8 | - | 0.9 | 1.4 | 17.2 | - | 580 | - | 1000 | D-12 | 690 | - |
10 | 1.83 | 0.7 | 0.8 | - | 1.25 | 1.5 | 19.6 | - | 850 | - | 1000 | D-12 | 960 | - |
16 | 1.15 | 0.7 | 0.8 | - | 1.25 | 1.6 | 22.2 | - | 1110 | - | 1000 | D-14 | 1260 | - |
25 | 0.727 | 0.9 | 1 | 0.8 | 1.6 | 1.7 | 24.3 | 23.2 | 1520 | 1420 | 500 | D-11 | 870 | 810 |
35 | 0.524 | 0.9 | 1 | 0.8 | 1.6 | 1.8 | 26.9 | 25.8 | 1910 | 1790 | 500 | D-12 | 1065 | 1010 |
50 | 0.387 | 1 | 1 | 0.8 | 1.6 | 1.8 | 30.1 | 29 | 2400 | 2250 | 500 | D-12 | 1350 | 1230 |
70 | 0.268 | 1.1 | 1 | 0.8 | 1.6 | 1.9 | 32.8 | 31.7 | 3100 | 2950 | 500 | D-14 | 1700 | 1630 |
95 | 0.193 | 1.1 | 1.2 | 0.8 | 2 | 2.1 | 38.2 | 36.7 | 4310 | 4060 | 500 | D-16 | 2400 | 2270 |
120 | 0.153 | 1.2 | 1.2 | 0.8 | 2 | 2.2 | 41.8 | 40.3 | 5170 | 4920 | 500 | D-18 | 2830 | 2700 |
150 | 0.124 | 1.4 | 1.4 | 0.8 | 2.5 | 2.3 | 46.4 | 44.5 | 6620 | 6290 | 500 | D-18 | 3550 | 3390 |
185 | 0.0991 | 1.6 | 1.4 | 0.8 | 2.5 | 2.4 | 50.8 | 48.9 | 7860 | 7510 | 250 | D-18 | 2210 | 2090 |
240 | 0.0754 | 1.7 | 1.4 | 0.8 | 2.5 | 2.6 | 56.9 | 55 | 9810 | 9410 | 250 | D-18 | 2690 | 2590 |
300 | 0.0601 | 1.8 | 1.6 | 0.8 | 2.5 | 2.7 | 61.8 | 59.5 | 11910 | 11430 | 250 | D-18 | 3220 | 3100 |
400 | 0.047 | 2 | 1.6 | 0.8 | 2.5 | 2.9 | 69.2 | 66.9 | 14910 | 14330 | 250 | D-19 | 3300 | 3110 |
*Circular solid conductors (Class 1).
Conductors including 16sqmm circular stranded (Class 2).
25sqmm and above shaped stranded conductors(Class 2)
Cables conform to BS 5467 and generally to IEC 60502-1.
600/1000V-FOUR CORE COPPER CONDUCTOR XLPE INSULATED PVC SHEATHED CABLES (CU/XLPE/PVC/SWA/PVC)
NOMINAL AREA OF CONDUCTOR | MAXIMUM CONDUCTOR RESISTANCE AT 20°C | THICKNESS OF INSULATION | THICKNESS OF BEDDING | DIA. OF ARMOUR WIRE | THICKNESS OF OUTER SHEATH | APPROX.OVERALL DIAMETER | APPROX.CABLE WEIGHT | STANDARD PACKING LENGTH | DRUM SIZE | APPROX.GROSS WEIGHT | ||||
Extruded Bedding | Lapped Bedding | Extruded Bedding | Lapped Bedding | Extruded Bedding | Lapped Bedding | Extruded Bedding | Lapped Bedding | |||||||
Sqmm | Ohm/Km | mm | mm | mm | mm | mm | Kg/Km | Metre±10% | KG | |||||
1.5* | 12.1 | 0.7 | 0.8 | - | 0.9 | 1.3 | 13.3 | - | 330 | - | 1000 | D-10 | 390 | - |
1.5 | 12.1 | 0.7 | 0.8 | - | 0.9 | 1.3 | 13.7 | - | 350 | - | 1000 | D-10 | 410 | - |
2.5* | 7.41 | 0.7 | 0.8 | - | 0.9 | 1.4 | 14.4 | - | 390 | - | 1000 | D-10 | 450 | - |
2.5 | 7.41 | 0.7 | 0.8 | 0.9 | 1.4 | 14.8 | - | 415 | - | 1000 | D-10 | 475 | - | |
4 | 4.61 | 0.7 | 0.8 | - | 0.9 | 1.4 | 15.9 | - | 490 | - | 1000 | D-11 | 590 | - |
6 | 3.08 | 0.7 | 0.8 | - | 0.9 | 1.4 | 17.2 | - | 580 | - | 1000 | D-12 | 690 | - |
10 | 1.83 | 0.7 | 0.8 | - | 1.25 | 1.5 | 19.6 | - | 850 | - | 1000 | D-12 | 960 | - |
16 | 1.15 | 0.7 | 0.8 | - | 1.25 | 1.6 | 22.2 | - | 1110 | - | 1000 | D-14 | 1260 | - |
25 | 0.727 | 0.9 | 1 | 0.8 | 1.6 | 1.7 | 24.3 | 23.2 | 1520 | 1420 | 500 | D-11 | 870 | 810 |
35 | 0.524 | 0.9 | 1 | 0.8 | 1.6 | 1.8 | 26.9 | 25.8 | 1910 | 1790 | 500 | D-12 | 1065 | 1010 |
50 | 0.387 | 1 | 1 | 0.8 | 1.6 | 1.8 | 30.1 | 29 | 2400 | 2250 | 500 | D-12 | 1350 | 1230 |
70 | 0.268 | 1.1 | 1 | 0.8 | 1.6 | 1.9 | 32.8 | 31.7 | 3100 | 2950 | 500 | D-14 | 1700 | 1630 |
95 | 0.193 | 1.1 | 1.2 | 0.8 | 2 | 2.1 | 38.2 | 36.7 | 4310 | 4060 | 500 | D-16 | 2400 | 2270 |
120 | 0.153 | 1.2 | 1.2 | 0.8 | 2 | 2.2 | 41.8 | 40.3 | 5170 | 4920 | 500 | D-18 | 2830 | 2700 |
150 | 0.124 | 1.4 | 1.4 | 0.8 | 2.5 | 2.3 | 46.4 | 44.5 | 6620 | 6290 | 500 | D-18 | 3550 | 3390 |
185 | 0.0991 | 1.6 | 1.4 | 0.8 | 2.5 | 2.4 | 50.8 | 48.9 | 7860 | 7510 | 250 | D-18 | 2210 | 2090 |
240 | 0.0754 | 1.7 | 1.4 | 0.8 | 2.5 | 2.6 | 56.9 | 55 | 9810 | 9410 | 250 | D-18 | 2690 | 2590 |
300 | 0.0601 | 1.8 | 1.6 | 0.8 | 2.5 | 2.7 | 61.8 | 59.5 | 11910 | 11430 | 250 | D-18 | 3220 | 3100 |
400 | 0.047 | 2 | 1.6 | 0.8 | 2.5 | 2.9 | 69.2 | 66.9 | 14910 | 14330 | 250 | D-19 | 3300 | 3110 |
600/1000V-FOUR CORE COPPER CONDUCTOR XLPE INSULATED PVC SHEATHED CABLES (CU/XLPE/PVC/SWA/PVC)
*All conductors shaped stranded(Class 2)
Cables conform to IEC 60502-1
Drum size given above are for cables with extruded bedding