• Bfou 150mm 0, 6/1 Kv Fire Resistance LSZH Power Cable

Bfou 150mm 0, 6/1 Kv Fire Resistance LSZH Power Cable

Type: Insulated
Conductor Type: Stranded
Application: Underground
Conductor Material: Copper
Sheath Material: Crosslinking
Insulation Material: XLPE
Samples:
US$ 35/Piece 1 Piece(Min.Order)
| Request Sample
Diamond Member Since 2018

Suppliers with verified business licenses

Trading Company

Basic Info.

Model NO.
BFOU
Material Shape
Round Wire
Range of Application
LSOH
Certification
ISO9001, CE, CCC, RoHS, VDE
Brand
Xcty
Cores Number
1 Core 2 Core 3 Core 4 Core 5 Cores
Green to Earth
LSZH
Safety
Fire Resistance
Voltage Level
0.6/1 Kv 6kv 11kv 15kv 33kv
Transport Package
Coil/Reel
Specification
150 sq mm
Trademark
XCTY
Origin
Zhengzhou
HS Code
8544492100
Production Capacity
2000000 Meters a Day

Product Description

BFOU 0,6/1 kV Electrolytic annealed tinned copper conductor fire resistance LSZH power cable
1. Object
 BFOU 0,6/1 kV type Cable.
2. Design This type of cable is designed, manufactured and tested according to IEC 60092-353 and NEK TS 606.
3. Applications For fixed installations offshore units in all locations. Cables for power circuits where shielding is required or areas that require additional protection against possible shock. All cable materials are free of halogens, with low fumes emission, fire retardant and fire resistant. These cables are especially suitable for the installation in ships in power, lighting and control circuits.
4. Characteristics Nominal voltage: 0,6/1 kV
Lowest installation temperature: -15 °C
Lowest ambient temperature for fixed installation: -40ºC
Maximum conductor operating temperature: 90 ºC
Maximum short-circuit conductor temperature: 250 °C (maximum 5 s)
Minimum bending radius: 6 x cable Ø No
flame propagation: according to IEC 60332-1-2 No
fire propagation: according to IEC 60332-3-22 (Category A)
Fire resistant: according to IEC 60331-21 (90 min. at 750 ºC) according to IEC 60331-2 / EN 50200 for Ø cable < 20 mm (120 min. at 840 ºC) according to IEC 60331-1 / EN 50362 for Ø cable > 20 mm (120 min. at 840 ºC)
Halogen free: Acid gas emission < 0,5 % according to IEC 60754-1 pH > 4,3 according to IEC 60754-2 conductivity < 10 µS/mm according to IEC 60754-2
Smoke emission: according to IEC 61034-2 light transmittance > 60 % Mud Resistant: according to NEK TS 606
Remarks: Including products for flame retardant, fire resistant and termite-proof
Packing: Export wooden drums

5.1 Conductor
(1) Electrolytic annealed tinned copper conductor, class 2 in accordance with IEC 60228, stranded with fine wires and flexibility level equivalent to class 5.
5.2 Insulation Mica tape (2) + Ethylene propylene (3), type EPR according to IEC 60092-360. The standard identification is the following: - 1 cond...........natural - 2 cond...........blue + brown - 3 cond...........brown + black + grey - 4 cond...........brown + black + grey + blue - ≥ 5 cond........white numbered Others colours under request.
5.3 Assembly of cores. The cores are twisted together.
5.4 Inner covering (4) Halogen free compound.
5.5 Braid/Armour (5) Braiding-armour of tinned copper wires.
5.6 Outer sheath (6) Mud resistant thermoset compound, black colour, with low smoke and halogen free under fire conditions, type SHF MUD

Bfou 150mm 0, 6/1 Kv Fire Resistance LSZH Power CableBfou 150mm 0, 6/1 Kv Fire Resistance LSZH Power CableBfou 150mm 0, 6/1 Kv Fire Resistance LSZH Power Cable
Bfou 150mm 0, 6/1 Kv Fire Resistance LSZH Power CableBfou 150mm 0, 6/1 Kv Fire Resistance LSZH Power Cable
1)3.6/6(7.2)kV,3.6/6.6(7.2)kV,Three Cores,Al or Cu/XLPE/CTS/STA/PVC Armoured Power Cable
 No.X Nominal Cross Section of Conductor  Nominal Diameter of Conductor  Nominal Thickness of Insulation  Nominal Thickness of Copper Tape Screen Nominal Thickness of Inner Sheath Nominal Thickness of Steel Tape Armouring Nominal Thickness of PVC Sheath Approx. Overall Diameter Approx. Weight
Al Conductor Cu Conductor 
No. X mm 2 mm mm mm mm mm mm mm kg/m kg/m
3 X 25 6 2.5 0.1 1.2 0.2 1.9 37.9 1.87 2.32
3 X 35 6.9 2.5 0.1 1.3 0.5 2 41.5 2.1 2.73
3 X50 8.2 2.5 0.1 1.3 0.5 2 44.3 2.37 3.22
3 X 70 9.7 2.5 0.1 1.4 0.5 2.1 47.9 2.77 4
3 X 95 11.3 2.5 0.1 1.4 0.5 2.2 51.6 3.21 4.91
3 X 120 12.8 2.5 0.1 1.5 0.5 2.4 55.4 3.69 5.84
3 X 150 14.2 2.5 0.1 1.5 0.5 2.5 58.6 4.15 6.85
3 X 185 15.9 2.5 0.1 1.5 0.5 2.6 62.5 4.73 8.11
3 X 240 18.3 2.6 0.1 1.6 0.5 2.7 68.5 5.62 10.05
3 X 300 20.4 2.8 0.1 1.7 0.5 2.9 74.5 6.55 12.11
3 X 400 23.2 3 0.1 1.9 0.8 3.2 83.6 8.78 15.86
3 X 500 26.4 3.2 0.1 2.1 0.8 3.4 93 10.52 18.85
2)6/10(12)kV,6.35/11(12)kV,,Three Cores,Al or Cu/XLPE/CTS/STA/PVC Armoured Power Cable
No.X Nominal Cross Section of Conductor  Nominal Diameter of Conductor  Nominal Thickness of Insulation  Nominal Thickness of Copper Tape Screen Nominal Thickness of Inner Sheath Nominal Thickness of Steel Tape Armouring Nominal Thickness of PVC Sheath Approx. Overall Diameter Approx. Weight
Al Conductor Cu Conductor 
No. X mm 2 mm mm mm mm mm mm mm kg/m kg/m
3 X 25 6 3.4 0.1 1.3 0.5 2 43.4 2.16 2.61
3 X 35 6.9 3.4 0.1 1.3 0.5 2 45.4 2.36 2.99
3 X50 8.2 3.4 0.1 1.4 0.5 2.2 48.8 2.69 3.54
3 X 70 9.7 3.4 0.1 1.5 0.5 2.3 52.4 3.1 4.33
3 X 95 11.3 3.4 0.1 1.5 0.5 2.4 56.1 3.56 5.26
3 X 120 12.8 3.4 0.1 1.5 0.5 2.5 59.5 4.04 6.19
3 X 150 14.2 3.4 0.1 1.5 0.5 2.6 62.7 4.49 7.19
3 X 185 15.9 3.4 0.1 1.6 0.5 2.6 66.6 5.12 8.49
3 X 240 18.3 3.4 0.1 1.7 0.5 2.8 72.4 5.99 10.42
3 X 300 20.4 3.4 0.1 1.8 0.5 3 77.5 6.86 12.42
3 X 400 23.2 3.4 0.1 1.9 0.8 3.2 85.4 8.97 16.05
3 X 500 26.4 3.4 0.1 2 0.8 3.4 93.7 10.65 19.5
3)8.7/10(15)kV,Three Cores,Al or Cu/XLPE/CTS/STA/PVC Armoured Power Cable
No.X Nominal Cross Section of Conductor  Nominal Diameter of Conductor  Nominal Thickness of Insulation  Nominal Thickness of Copper Tape Screen Nominal Thickness of Inner Sheath Nominal Thickness of Steel Tape Armouring Nominal Thickness of PVC Sheath Approx. Overall Diameter Approx. Weight
Al Conductor Cu Conductor 
No. X mm 2 mm mm mm mm mm mm mm kg/m kg/m
3 X 25 6 4.5 0.1 1.4 0.5 2.1 48.6 2.53 2.98
3 X 35 6.9 4.5 0.1 1.4 0.5 2.2 50.7 2.76 3.39
3 X50 8.2 4.5 0.1 1.5 0.5 2.3 53.9 3.1 3.95
3 X 70 9.7 4.5 0.1 1.5 0.5 2.4 57.4 3.51 4.74
3 X 95 11.3 4.5 0.1 1.5 0.5 2.6 61.2 4.05 5.75
3 X 120 12.8 4.5 0.1 1.6 0.5 2.6 64.7 4.56 6.72
3 X 150 14.2 4.5 0.1 1.6 0.5 2.7 67.9 5.04 7.74
3 X 185 15.9 4.5 0.1 1.7 0.5 2.8 71.9 5.66 9.04
3 X 240 18.3 4.5 0.1 1.8 0.5 3 77.7 6.56 11
3 X 300 20.4 4.5 0.1 1.9 0.8 3.2 84.1 8.39 13.96
3 X 400 23.2 4.5 0.1 2 0.8 3.3 90.5 9.71 16.79
3 X 500 26.4 4.5 0.1 2.1 0.8 3.5 98.8 11.45 20.57
4)12/20(24)kV, 12.7/22(24)kV,Three Cores,Al or Cu/XLPE/CTS/STA/PVC Armoured Power Cable
No.X Nominal Cross Section of Conductor  Nominal Diameter of Conductor  Nominal Thickness of Insulation  Nominal Thickness of Copper Tape Screen Nominal Thickness of Inner Sheath Nominal Thickness of Steel Tape Armouring Nominal Thickness of PVC Sheath Approx. Overall Diameter Approx. Weight
Al Conductor Cu Conductor 
No. X mm 2 mm mm mm mm mm mm mm kg/m kg/m
3 X 25                  
3 X 35 6.9 5.5 0.1 1.5 0.5 2.4 55.6 3.14 3.77
3 X50 8.2 5.5 0.1 1.5 0.5 2.5 58.6 3.49 4.34
3 X 70 9.7 5.5 0.1 1.5 0.5 2.6 62.1 3.93 5.16
3 X 95 11.3 5.5 0.1 1.6 0.5 2.6 65.7 4.46 6.16
3 X 120 12.8 5.5 0.1 1.7 0.5 2.7 69.4 5 7.15
3 X 150 14.2 5.5 0.1 1.7 0.5 2.8 72.6 5.49 8.19
3 X 185 15.9 5.5 0.1 1.8 0.5 3 76.9 6.16 9.53
3 X 240 18.3 5.5 0.1 1.9 0.8 3.2 83.9 7.87 12.31
3 X 300 20.4 5.5 0.1 2 0.8 3.2 88.6 8.96 14.52
3 X 400 23.2 5.5 0.1 2.1 0.8 3.5 95.4 10.35 17.43
3 X 500 26.4 5.5 0.1 2.2 0.8 3.7 103.7 12.45 20.23
5)18/30(36)kV,19/33(36)kV,Three Cores,Al or Cu/XLPE/CTS/STA/PVC Armoured Power Cable
No.X Nominal Cross Section of Conductor  Nominal Diameter of Conductor  Nominal Thickness of Insulation  Nominal Thickness of Copper Tape Screen Nominal Thickness of Inner Sheath Nominal Thickness of Steel Tape Armouring Nominal Thickness of PVC Sheath Approx. Overall Diameter Approx. Weight
Al Conductor Cu Conductor 
No. X mm 2 mm mm mm mm mm mm mm kg/m kg/m
3 X 25                  
3 X 35                  
3 X50 8.2 8 0.1 1.7 0.5 2.8 70.4 4.56 5.41
3 X 70 9.7 8 0.1 1.7 0.5 2.9 73.9 5.04 6.26
3 X 95 11.3 8 0.1 1.8 0.5 3 77.7 5.62 7.32
3 X 120 12.8 8 0.1 1.9 0.8 3.2 82.8 6.99 9.15
3 X 150 14.2 8 0.1 1.9 0.8 3.2 85.8 7.56 10.26
3 X 185 15.9 8 0.1 2 0.8 3.3 89.9 8.3 11.67
3 X 240 18.3 8 0.1 2.1 0.8 3.5 95.7 9.36 13.79
3 X 300 20.4 8 0.1 2.2 0.8 3.6 100.6 10.51 16.07
3 X 400 23.2 8 0.1 2.3 0.8 3.8 107.2 11.99 19.07
3 X 500 26.4 8 0.1 2.4 0.8 4 120.1 14.15 23.85
 

products of our company cover:
1. hook up wire
2. XLPVC/XLFRPE/XLPE wire(UL.VDE, ROHS)
3. Shied wire
4. Coaxial cable
5. High-temperature wire
6. Flat cable
7. Computer cable
8. Underground distribution line cable with voltage under 36000V
9. Transmission line conductor and cable with LV & MV
10. Tinned copper wire, bare copper wire, aluminum wire, steel wire
11. Copper bar, copper rod, aluminum rod, aluminum tape, aluminum sheet

Any interesting item about the above and  UL Electric Wire Cable, welcome to contact us freely, the first-hand price will strengthen your business, thanks.
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now