Basic Info.

Model NO.
ABC cable
Conductor Material
Aluminum
Sheath Material
Crosslinking
Insulation Material
PE
Material Shape
Round Wire
Range of Application
LSOH
Certification
ISO9001, CE, CCC, RoHS
Brand
Xcty
Cores Number
Duplex, Triplex Cable
Conductor Size
70 mm
Quality
36 Months
Messenger Conductor
AAC AAAC ACSR
Transport Package
Coil/Reel
Specification
16 sqmm
Trademark
XCTY
Origin
Guangzhou
HS Code
854492100
Production Capacity
2000000 Meters a Day

Product Description

AAC Phase Conductor with Triplex Service Drop Cable

Application

Aerial Bundle Cable (ABC cable) is a very innovative concept for overhead power distribution as compared to the conventional bare conductor overhead distribution system.

It provides higher level of safety and reliability, lower power losses and ultimate system economy by reducing installation, maintenance and operative cost.

Caledonian LV Aerial Bundle Cables are designed to supply 600/1000 volt aerial service for temporary service at construction sites, as a service drop (power pole to service entrance), as a secondary cable (pole to pole) or street lighting.

This over-head cable provides reinforced insulation acc. IEC 61140 and fulfill therefore Class II acc. IEC 61140. It is not flame retardant. But this could be if requested change to a flame retardant cable.

Standard

Basic design to BS 7870 / TNB Specification(IEC 60502) / HD 626 S1 / NFC 33-209 / AS/NZS 3560-1 standards

Construction

Electrical Properties

Rated Voltage 0.6/1kV
Test Voltage 4 Veff kV
Minimum Laying Temperature -20°C
Operating Temperature -40°C~ +90°C
Maximum Short-circuit Temperature 250°C
Maximum Conductor Temperature 80°C
Minimum Bending Radius 18×OD

Construction Parameters

Standards:
1. B-230 Aluminum Wire, 1350-H19 for Electrical Purposes.
2. B-231 Aluminum Conductors, Concentric-Lay-Stranded.
3. B-232 Aluminum Conductors, Concentric-Lay-Stranded, Coated Steel Reinforced (ACSR).
4. B-399 Concentric-Lay_Stranded 6201-T81 Aluminum Alloy Conductors.
5. B498 Zinc-Coated Steel Core Wire for Aluminum Conductors, Steel Reinforced (ACSR).
6. Duplex Service Drop cable meets or exceeds all applicable requirements of ANSI/ICEA S-76-474Cord word Phase conductor Bare neutral messenger Nominal lay length Weight per 1000ft (ibs) Allowable AMP cities

Cord word Phase conductor Bare neutral messenger Nominal lay length Weight per 1000ft (ibs) Allowable AMP cities
Size
(AWG) Stranding Insul. Thick(Mils) Size
(AWG) Stranding Pated strength(ibs) inches XLPE PE XLPE PE
AAC Neutral-messenger
Cord word Phase conductor Bare neutral messenger Nominal lay length Weight per 1000ft (ibs) Allowable amp cities
Size
(AWG)
Stranding Insul. Thick(Mils) Size
(AWG)
Stranding Pated strength(ibs) inches XLPE PE XLPE PE
AAC Neutral-messenger
Pekingese 6 1 45 6 7 563 10.36 61 61 85 70
Collie 6 7 45 6 7 563 10.36 64 64 85 70
Dachshund 4 1 45 4 7 881 10.36 92 92 115 90
Spaniel 4 7 45 4 7 881 10.36 96 96 115 90
Doberman 2 7 45 2 7 1350 14.88 147 147 150 120
Malamute 1/0 9 60 1/0 7 1990 14.88 234 234 205 160

 

Other cross-sections can be offered upon request.

NFC 33-209

Number of Cores x Nominal Cross Section Overal Diameter Weight Maximum Conductor Resistance Minimum Breaking Load Current Rating
No.×mm^2 mm Kg/Km Ω/Km KN A
2x10 RM 12.8 93 3.080 1.5 38
4x10 RM 15.4 183 3.080 1.5 38
2x16 RM 14.8 129 1.910 2.3 72
2x16 RN + 2x1.5 RE 14.8 176 1.910/12.100 2.3 72
4x16 RM 17.8 257 1.910 2.3 72
4x16 RN + 2x1.5 RE 17.8 304 1.910/12.100 2.3 72
2x25 RM 18.0 202 1.200 3.8 107
2x25 RM + 2x1.5 RE 18.0 249 1.200/12.100 3.8 107
4x25 RM 21.7 404 1.200 3.8 107
4x25 RM + 2x1.5 RE 21.7 451 1.200/12.100 3.8 107
2x35 RM 20.8 269 0.868 5.2 132
2x35 RM + 2x1.5 RE 20.8 316 0.868/12.100 5.2 132
4x35 RM 25.1 539 0.868 5.2 132
4x35 RM + 2x1.5 RE 25.1 586 0.868/12.100 5.2 132
2x50 RM 23.4 352 0.641 7.6 165
2x50 RM + 2x1.5 RE 23.4 399 0.641/12.100 7.6 165
1x54.6 RM + 3x25 RM 21.7 507 0.630/1.200 3.8 107
1x54.6 RM + 3x25 RM + 1x16 RM 24.3 573 0.630/1.200/1.910 3.8/2.3 107/72
1x54.6 RM + 3x25 RM + 2x16 RM 29.7 639 0.630/1.200/1.910 3.8/2.3 107/72
1x54.6 RM + 3x25 RM + 3x16 RM 31.1 705 0.630/1.200/1.910 3.8/2.3 107/72
1x54.6 RM + 3x35 RM 25.1 615 0.630/0.868 5.2 132
1x54.6 RM + 3x35 RM + 1x16 RM 28.1 680 0.630/0.868/1.910 5.2/2.3 132/72
1x54.6 RM + 3x35 RM + 2x16 RM 34.3 748 0.630/0.868/1.910 5.2/2.3 132/72
1x54.6 RM + 3x35 RM + 3x16 RM 35.9 814 0.630/0.868/1.910 5.2/2.3 132/72
1x54.6 RM + 3x35 RM + 1x25 RM 28.1 714 0.630/0.868/1.200 5.2/3.8 132/107
1x54.6 RM + 3x50 RM 28.2 741 0.630/0.641 7.6 165
1x54.6 RM + 3x50 RM + 1x16 RM 31.6 806 0.630/0.641/1.910 7.6/2.3 165/72
1x54.6 RM + 3x50 RM + 2x16 RM 38.6 875 0.630/0.641/1.910 7.6/2.3 165/72
1x54.6 RM + 3x50 RM + 3x16 RM 40.4 940 0.630/0.641/1.910 7.6/2.3 165/72
1x54.6 RM + 3x50 RM + 1x25 RM 31.6 841 0.630/0.641/1.200 7.6/3.8 165/107
1x54.6 RM + 3x70 RM 33.0 950 0.630/0.443 10.2 205
1x54.6 RM + 3x70 RM + 1x16 RM 37.0 1014 0.630/0.443/1.910 10.2/2.3 205/72
1x54.6 RM + 3x70 RM + 2x16 RM 45.2 1083 0.630/0.443/1.910 10.2/2.3 205/72
1x54.6 RM + 3x70 RM + 3x16 RM 47.3 1148 0.630/0.443/1.910 10.2/2.3 205/72
1x54.6 RM + 3x70 RM + 1x25 RM 37.0 1048 0.630/0.443/1.200 10.2/3.8 205/107
1x54.6 RM + 3x70 RM + 2x25 RM 45.2 1150 0.630/0.443/1.200 10.2/3.8 205/107
1x54.6 RM + 3x70 RM + 3x25 RM 47.3 1250 0.630/0.443/1.200 10.2/3.8 205/107
1x54.6 RM + 3x95 RM 37.4 1176 0.630/0.320 13.5 240
1x54.6 RM + 3x95 RM + 1x16 RM 41.9 1243 0.630/0.320/1.910 13.5/2.3 240/72

AAC Phase Conductor with Triplex Service Drop CableAAC Phase Conductor with Triplex Service Drop Cable

more information on cable,welcome to contact us freely,thanks

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier