Lxs Aluminium Overhead Aerial Cable for Overhead Power Distribution 70mm
Henan XinChang Import and Export Trade Co., Ltd.
Henan, China
Last Login Date:
Jun 11, 2025
Business Type:
Manufacturer/Factory
Main Products:
Aluminum Coil, Aluminum Sheet, Aluminum Foil, Aluminum Plate, Aluminum Alloy, Mirror Finished Aluminum Sheet, Embossed Aluminum Sheet, Color Coated Aluminum Sheet/Foil, Aluminum Chequered Plate
Product Description
Company Info
Basic Info.
Product Description
Duplex AAC/ACSR Conductor Overhead Power Transmission Used XLPE Twisted ABC Power Cable
Application
Aerial Bundle Cable (ABC cable) is a very innovative concept for overhead power distribution as compared to the conventional bare conductor overhead distribution system.
It provides higher level of safety and reliability, lower power losses and ultimate system economy by reducing installation, maintenance and operative cost.
Caledonian LV Aerial Bundle Cables are designed to supply 600/1000 volt aerial service for temporary service at construction sites, as a service drop (power pole to service entrance), as a secondary cable (pole to pole) or street lighting.
This over-head cable provides reinforced insulation acc. IEC 61140 and fulfill therefore Class II acc. IEC 61140. It is not flame retardant. But this could be if requested change to a flame retardant cable.
Standard
Basic design to BS 7870 / TNB Specification(IEC 60502) / HD 626 S1 / NFC 33-209 / AS/NZS 3560-1 standards
Construction
Conductor | Aluminium conductor, round stranded compressed (RM).1350 aluminum wire |
Insulation | XPLE compound, UV-resistant. |
Core Identification | 1, 2 resp. 3 raised longitudinal ribs on the surface of the cores. The surface of the neutral core should have at least 12 ribs for cross-sections up to 50 mm^2 and a minimum of 16 ribs for cores above 50 mm^2. In the case of five core bundles the surface of the protective core should be smooth. |
Electrical Properties
Rated Voltage | 0.6/1kV |
Test Voltage | 4 Veff kV |
Minimum Laying Temperature | -20°C |
Operating Temperature | -40°C~ +90°C |
Maximum Short-circuit Temperature | 250°C |
Maximum Conductor Temperature | 80°C |
Minimum Bending Radius | 18×OD |
Construction Parameters
CODE* WORD | PHASE CONDUCTOR | BARE NEUTRAL MESSENGER | WEIGHT PER 1000 FT.(LBS.) | ALLOWABLE AMPACITIES+ | |||||||
Size (AWG | Strand- ing | Insul. Thick. (mils) | Equiv. Dia. (AWG)++ | Size++ (kcmil) | Strand- ing | Rated Strength (lbs). | XLP | POLY | XLP | POLY | |
6201 ALLOY NEUTRAL-MESSENGER | |||||||||||
Minex | 6 | 1 | 45 | 6 | 30.58 | 7 | 1110 | 101 | 101 | 85 | 70 |
Hippa | 6 | 7 | 45 | 6 | 30.58 | 7 | 1110 | 107 | 107 | 85 | 70 |
Prawn | 4 | 1 | 45 | 4 | 48.69 | 7 | 1760 | 152 | 152 | 115 | 90 |
Barnacle | 4 | 7 | 45 | 4 | 48.69 | 7 | 1760 | 160 | 160 | 115 | 90 |
Shrimp | 2 | 7 | 45 | 2 | 77.47 | 7 | 2800 | 243 | 243 | 150 | 120 |
Gammarus | 1/0 | 7 | 60 | 1/0 | 123.3 | 7 | 4460 | 390 | 390 | 205 | 160 |
Leda | 1/0 | 9 | 60 | 1/0 | 123.3 | 7 | 4460 | 384 | 384 | 205 | 160 |
Dungenese | 2/0 | 7 | 60 | 2/0 | 155.4 | 7 | 5390 | 483 | 483 | 235 | 185 |
Cyclops | 2/0 | 11 | 60 | 2/0 | 155.4 | 7 | 5390 | 474 | 474 | 235 | 185 |
Flustra | 3/0 | 17 | 60 | 3/0 | 195.7 | 7 | 6790 | 587 | 587 | 275 | 215 |
Lepas | 4/0 | 18 | 60 | 4/0 | 246.9 | 7 | 8560 | 728 | 728 | 315 | 245 |
*Code words for XLP insulated products are formed by adding "/XLP" to the conventional code words above (e.g.-Haiotis/XLP). +Conductor temperature of 90°C for XLP, 75°C for Poly; ambient temperature of 40°C; emissivity 0.9; 2 ft./sec. wind in sun. ++Designated sizes are: ACSR 6/1 diameter equivalent and AAC with equivalent resistivity per ASTM B-399 for 6201. |
CODE* WORD | PHASE CONDUCTOR | BARE NEUTRAL MESSENGER | WEIGHT PER 1000 FT. (LBS.) | ALLOWABLE AMPACITIES+ | |||||||
Size (AWG) | Strand- ing | Insul. Thick. (mils) | Equiv. Dia. (AWG)++ | Size (kcmil) | Strand- ing | Rated Strength (lbs.) | XLP | POLY | XLP | POLY | |
6201 ALLOY REDUCED NEUTRAL-MESSENGER | |||||||||||
Artemia | 4 | 1 | 45 | 6 | 30.58 | 7 | 1110 | 135 | 135 | 115 | 90 |
Crab | 4 | 7 | 45 | 6 | 30.58 | 7 | 1110 | 143 | 143 | 115 | 90 |
Solaster | 2 | 7 | 45 | 4 | 48.69 | 7 | 1760 | 216 | 216 | 150 | 120 |
Sandcrab | 1/0 | 7 | 60 | 2 | 77.47 | 7 | 2800 | 347 | 347 | 205 | 160 |
Echinus | 1/0 | 9 | 60 | 2 | 77.47 | 7 | 2800 | 341 | 341 | 205 | 160 |
Fulgar | 3/0 | 17 | 60 | 1/0 | 123.3 | 7 | 4460 | 519 | 519 | 275 | 215 |
Arca | 4/0 | 18 | 60 | 2/0 | 155.4 | 7 | 5390 | 643 | 643 | 315 | 245 |
*Code words for XLP insulated products are formed by adding "/XLP" to the conventional code words above (e.g.-Haiotis/XLP). +Conductor temperature of 90°C for XLP, 75°C for Poly; ambient temperature of 40°C; emissivity 0.9; 2 ft./sec. wind in sun. ++Designated sizes are: ACSR 6/1 diameter equivalent and AAC with equivalent resistivity per ASTM B-399 for 6201. |