• Covered Line Wire and Cable 600V Overhead Secondary Power Distribution Cable
  • Covered Line Wire and Cable 600V Overhead Secondary Power Distribution Cable
  • Covered Line Wire and Cable 600V Overhead Secondary Power Distribution Cable
  • Covered Line Wire and Cable 600V Overhead Secondary Power Distribution Cable
  • Covered Line Wire and Cable 600V Overhead Secondary Power Distribution Cable
  • Covered Line Wire and Cable 600V Overhead Secondary Power Distribution Cable

Covered Line Wire and Cable 600V Overhead Secondary Power Distribution Cable

Type: Insulated
Conductor Type: Stranded
Application: Overhead
Conductor Material: Aluminum
Sheath Material: Crosslinking
Insulation Material: PE
Diamond Member Since 2018

Suppliers with verified business licenses

Trading Company

Basic Info.

Model NO.
JKLYJ
Material Shape
Round Wire
Range of Application
LSOH
Certification
ISO9001, CE, CCC, RoHS
Brand
Xcty
Voltage
600V Cable
Size
120mm
Quality
36 Months
Standard
IEC ASTM BS Icea
Transport Package
Coil/Reel
Specification
16 sqmm
Trademark
XCTY
Origin
Guangzhou
HS Code
854492100
Production Capacity
2000000 Meters a Day

Product Description

Covered Line Wire and Cable 600V overhead secondary Power distribution cable

Application

Aerial Bundle Cable (ABC cable) is a very innovative concept for overhead power distribution as compared to the conventional bare conductor overhead distribution system.

It provides higher level of safety and reliability, lower power losses and ultimate system economy by reducing installation, maintenance and operative cost.

Caledonian LV Aerial Bundle Cables are designed to supply 600/1000 volt aerial service for temporary service at construction sites, as a service drop (power pole to service entrance), as a secondary cable (pole to pole) or street lighting.

This over-head cable provides reinforced insulation acc. IEC 61140 and fulfill therefore Class II acc. IEC 61140. It is not flame retardant. But this could be if requested change to a flame retardant cable.

Standard

Basic design to BS 7870 / TNB Specification(IEC 60502) / HD 626 S1 / NFC 33-209 / AS/NZS 3560-1 standards

Construction

   
Conductor Aluminium conductor, round stranded compressed (RM).
Insulation XPLE compound, UV-resistant.
Core Identification 1, 2 resp. 3 raised longitudinal ribs on the surface of the cores. The surface of the neutral core should have at least 12 ribs for cross-sections up to 50 mm^2 and a minimum of 16 ribs for cores above 50 mm^2. In the case of five core bundles the surface of the protective core should be smooth.

Electrical Properties

Rated Voltage 0.6/1kV
Test Voltage 4 Veff kV
Minimum Laying Temperature -20°C
Operating Temperature -40°C~ +90°C
Maximum Short-circuit Temperature 250°C
Maximum Conductor Temperature 80°C
Minimum Bending Radius 18×OD

Construction Parameters

CODE

 

WORD

EQUIV DIA

 

(AWG)*

SIZE

 

(KCMIL)

STRAND- ING COVER THICKNESS (MILS) TOTAL DIAMETER (MILS) RATED STRENGTH (LBS.) WEIGHT PER 1000 FT. (LBS.) ALLOWABLE

 

AMPACITY+

XLP Conv. Poly HD Poly
6201 ALUMINUM Alloy
Hornbeam 4 48.69 7 30 310 1360 60 60 - 145
Linden 2 77.47 7 45 406 2160 99 99 - 190
Oilnut 1/0 123.3 7 60 518 3440 159 159 - 250
Waterash 2/0 155.4 7 60 567 4160 195 195 - 290
Shellbark 3/0 195.7 7 60 622 5240 240 240 - 335
Planetree 4/0 246.9 7 60 683 6610 297 297 - 385
 
*Diameter equivalent to ACSR construction or 1350 aluminum equivalent.

 

+Ampacity ratings based on 75°C conductor temperature 25°C ambient temperature elevation - sea level. Emissivity 0.91 coefficient of absorption 0.95. Thermal resistivity of covering - 375°C M /Watt-CM.

Wind speed 2 ft./sec. in sun.

 

 

CODE

 

WORD

SIZE (AWG OR KCMIL) STRAND- ING COVER THICKNESS (MILS) TOTAL DIAMETER (MILS) RATED STRENGTH (LBS.) WEIGHT PER 1000 FT. (LBS.) ALLOWABLE

 

AMPACITY+

XLP Conv. Poly HD Poly
ALL- ALUMINUM
Apple 6 1 30 222 445 31 31 - 105
Plum 6 7 30 238 510 56 34 - 105
Pear 4 1 30 264 710 47 47 - 135
Apricot 4 7 30 285 790 51 51 - 140
Cherry 2 1 45 348 1100 78 78 - 180
Peach 2 7 45 373 1220 84 84 85 180
Nectarine 1 7 45 408 1470 104 104 - 210
Quince 1/0 7 60 477 1790 136 136 - 240
Orange 2/0 7 60 522 2260 167 167 - 280
Fig 3/0 7 60 570 2740 205 205 - 320
Olive 4/0 7 60 626 3450 253 253 - 370
Pomegranate 4/0 19 60 632 3620 247 247 - 370
Mulberry 266.8 19 60 694 4470 305 305 - 430
Annona 336.4 19 60 765 5540 377 377 - 495
Molles 397.5 19 80 861 6400 462 462 - 545
Huckleberry 477 37 80 931 7820 538 538 - 610
Paw Paw 556.5 37 80 992 8950 619 619 - 670
Breadfruit 636.0 61 95 1081 10500 715 715 - 720
Persimmon 795 61 95 1186 12900 877 877 881 825
Grapefruit 1033.5 61 95 1326 16500 - 1118 - 970
 
+Ampacity ratings based on 75°C conductor temperature 25°C ambient temperature elevation - sea level. Emissivity 0.91 coefficient of absorption 0.95. Thermal resistivity of covering - 375°C M /Watt-CM.

 

Wind speed 2 ft./sec. in sun.

 
CODE

 

WORD

SIZE (AWG OR KCMIL) STRAND- ING COVER THICKNESS (MILS) TOTAL DIAMETER (MILS) RATED STRENGTH (LBS.) WEIGHT PER 1000 FT. (LBS.) ALLOWABLE

 

AMPACITY+

XLP Conv. Poly HD Poly
ACSR
Walnut 6 6/1 30 258 1130 47 47 47 105
Butternut 4 6/1 30 310 1770 72 72 72 135
Hickory 4 7/1 30 317 2240 83 83 84 135
Pignut 2 6/1 45 406 2710 118 118 119 180
Beech 2 7/1 45 415 3460 136 136 137 180
Chestnut 1 6/1 45 444 3370 145 145 - 210
Almond 1/0 6/1 60 518 4160 190 190 191 235
Pecan 2/0 6/1 60 567 5040 233 233 235 270
Filbert 3/0 6/1 60 622 6290 288 288 290 305
Buckeye 4/0 6/1 60 683 7930 357 357 359 345
Hackberry 266.8 18/1 60 729 6540 354 354 - 435
 
+Ampacity ratings based on 75°C conductor temperature 25°C ambient temperature elevation - sea level. Emissivity 0.91 coefficient of absorption 0.95. Thermal resistivity of covering - 375°C M /Watt-CM.

 

Wind speed 2 ft./sec. in sun.

 

Packaging:

a. Wooden drum

b. Iron frame wooden drum

c. Iron drum

Container loading:

a. 20ft GP: 5898mm(Length)x2352mm(Width)x2393(High), loading: 18-25tons;

b. 40ft GP: 12032mm(Length)x2352mm(Width)x2393(High), loading: 20-28tons;

Port:

Qingdao port or other China main ports
Covered Line Wire and Cable 600V Overhead Secondary Power Distribution CableCovered Line Wire and Cable 600V Overhead Secondary Power Distribution Cable

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now